This is a high-value oral area. For A, B and C class divisions, avoid short answers such as “A is the strongest.” A stronger answer gives the construction, fire-test integrity, insulation temperature limits and practical inspection points.
A-class division
Formed by bulkheads and decks. Constructed of steel or equivalent material, suitably stiffened, and insulated as required. It must prevent the passage of smoke and flame to the end of the one-hour standard fire test.
B-class division
Formed by bulkheads, decks, ceilings or linings. Constructed of approved non-combustible materials. It must prevent passage of flame to the end of the first 30 minutes of the standard fire test.
C-class division
Constructed of approved non-combustible materials. It does not have the A/B class requirements for smoke/flame integrity or insulation temperature-rise performance.
| Division |
Construction |
Fire-test integrity |
Temperature-rise / insulation criteria |
| A-class |
Steel or equivalent; suitably stiffened; formed by bulkheads and decks. |
Prevents passage of smoke and flame to the end of the one-hour standard fire test. |
Average unexposed side rise ≤ 140°C; any point including joints ≤ 180°C during the rated period: A-0, A-15, A-30 or A-60. |
| B-class |
Approved non-combustible materials; formed by bulkheads, decks, ceilings or linings. |
Prevents passage of flame to the end of the first half hour of the standard fire test. |
Average unexposed side rise ≤ 140°C; any point ≤ 225°C during the rated period: B-0 or B-15. |
| C-class |
Approved non-combustible materials. |
No A/B smoke or flame integrity requirement. |
No A/B insulation temperature-rise rating. |
What does A-60 mean?
A-60 is not a door-closing time. It means an A-class division maintains its integrity in the standard fire test and its insulation keeps the unexposed side within the required temperature-rise limits for 60 minutes.
What does B-15 mean?
B-15 means a B-class division prevents flame passage for the standard B-class integrity requirement and maintains the B-class insulation temperature-rise limits for 15 minutes.
Main vertical fire zone
A main vertical zone is a section of the hull, superstructure or deckhouse divided by A-class divisions. Its purpose is to prevent or limit the horizontal spread of smoke and flames, supporting containment, escape and firefighting control.
Doors and penetrations
- Doors in fire boundaries must preserve the fire integrity of the division.
- Fire doors must self-close / latch correctly where required and must not be wedged open.
- Cable and pipe penetrations must be properly approved and sealed.
- Bad penetrations defeat the fire boundary even if the steel bulkhead is intact.
Common mistake: do not call every fire boundary A-60. State the correct class and rating only where it is required by the fire integrity tables and approved drawings.
Oral prompt
“Define an A-class bulkhead in full. Then define B-class and C-class divisions, explain the temperature-rise criteria, and tell me why main vertical fire zones are used.”